| Neutral connection required |
| Ground connection not needed |
| Dimmer can communicate with wireless devices up to 30' away through walls, and 60' away if you have line-of-sight |
|
Troubleshooting |
| Problem: Light does not turn on |
| Make sure dimmer is being used with a Lutron 3-wire ballast or driver |
| Problem: Bulbs flicker once every 6-8 seconds when trying to turn on |
| Could be a problem with the lamp socket wiring. See Troubleshooting Guide |
| Problem: Bulbs flicker when dimmed |
| Make sure bulbs in use are compatible with the ballast/driver/interface controlling them |
| Check to make sure the dimmed hot and switched hot wires are not reversed |
| If being used in a multi-location application, make sure only one master dimmer is in use. Companion dimmers, such as model MA-R, should be used in the other locations
|